2019狠狠的啪中文字幕_激情五月开心日国产_无码人妻1区2区3区_日韩人妻高清精品专区丨

Welcome to the official website of Xingtai Degang Electronics Co., Ltd!
邢臺德港電子有限公司
keywords:
news information INDEX > news information > News Center > Common fault of hook scale and its solution

Common fault of hook scale and its solution

Time:2020.06.24     News sources: Hebei Chaoda Sealing Products Co., Ltd

Common fault of hook scale and its solution

1, the electronic crane scale does not turn on

Check the maintenance personnel before maintenance to confirm whether it is caused by the problem of fuse, power back switch, power line, etc.

Check whether the transformer of electronic crane scale has AC110V/220V input voltage and corresponding output voltage.

Remove the battery and use a multimeter to check whether the battery voltage is normal. If the voltage is lower than the specified voltage, please charge; If the battery shows no power after full charge, please replace the battery.

2. Electronic crane scale is not displayed

Check whether the battery in the machine is low voltage caused by automatic shutdown.

Whether the fuse is blown (using ac).

3. The electronic crane scale cannot be charged

Check whether the supply voltage is in accordance with the voltage marked on the product.

Whether the fuse is blown (using ac).

4, electronic crane scale number jump

Is the sensor connected well?

Whether the sensor and display are damp, and whether the sensor setting is too small.

Whether the AD conversion rate is set too high, whether there is vibration, wind and other interference.

Whether the scale body touches foreign body.

5. Electronic crane scale with printing function cannot be printed

Whether the printer type is set correctly, the reading is stable, and the stability marker is bright.

Whether the printer connection is plugged in, whether the printer is online.

6. Electronic crane scales cannot accumulate

Is it zero before accumulation? Is it stable when pressing the accumulation key?

7. Unable to communicate through serial port

Baud rate, send mode Settings are correct

Is the connection of RS-232C in good condition?

8. Power on does not return to zero

The automatic zero range setting is too small.

Is there any dirt on the weigher?

9. Manual reset is invalid

The manual reset range setting is too small.

Is the current reading stable?

10. Electronic crane scales cannot be weighed

Whether it has been calibrated (linear calibration must be done first if there is a linear calibration type).

≡  contacts:Manager Wang ≡  mobile:13930926376 ≡  Telephone:0319-2158243 ≡  fax:0319-2159641 ≡  address:No. 1 in Rongtai science and Technology Incubation Park, south of Xingda street, Xingtai Economic Development Zone
河北超達密封
版權(quán)所有:邢臺德港電子有限公司       網(wǎng)站備案/許可證號:       

冀公網(wǎng)安備 13050902000085號

技術(shù)支持:邢臺市網(wǎng)商軟件開發(fā)有限公司